
Add: Room 2001、2002、2003、2011, Zhonghai International Plaza No. 237, Wannianquan Road, Qingdao, Shandong 266199 China
Tel: +86 532 8281 2277
Mobile : +86 186 5320 8877(WhatsApp)
Email: market@hiprove.cn lena@hiprove.cn


Part parameters
- Packaging Details:
- Delivery Time:
- Description:
Detailed introduction:
BN-200 Infant Radiant Warmer
Brief introduction:
• Three mode of control: manual,skin temperature and mattress temperature
• Alloyed bracket, fastness
• Microprocessor based servo controlled temperature system
• Control panel disp layed by VFD
• Digital skin temperature sensor, the data is exact and stabilizability
• High sensitivity and untouched detector to inspect mattress temperature
• Alarms functions for safety includes power failure temperature deviation temperature probe failure over temperature
• Integral timer to record therapy time
• Observe light angle can be adjusted 360° , and the brightness adjusted
• Heater head can be adjusted :±90°horizontally
• Electric infant bed tilt angle is: ±10° transparent protector folded
• Convenient X-ray cassette under infant bed
• Electric height adjusted suit for operation
Standard configuration
Main body (including the radiant source ,control system ,infant bed, electric lift stand),
I. V.pole , skin sensor, mattress , one drawer, transparent protector, castors
Functions features
Adopts anti-explsion micro crystal quartz infrared radiation tube for its radiation source ,
the heating is quick and life-span is long
Alarms are audibility and visually
A second thermal cut-out function for more safety
Skin temperature sensor failure protect function avoid over temperature
Technical data
• Power supply : 110/220V 50/60Hz
• Power input: ≤1000VA
• Operating condition
An ambient Temperature: 18℃ - 30℃
An ambient Relative Humidity: 30%- 75%RH
Atmospheric Pressure: 700~ 1060hPa
An ambient Air Velocity: < 0.3m/s
• Temperature control: 32℃ ~38℃
• Temperature control accuracy: ≤0.5℃
• Alarms functions
a. Over temperatuer : > 39℃
b. A sencond thermal cut- out : 40℃
c. Sensor alarm: skin temperature sensor failure matterss temperature sensor failure room temperature sensor failure
d. Power failure
• Mattress temperature uniformity:<2 ℃
• Skin temperature sensor accuracy: ≤0.3 ℃
• Mattress temperature sensor accuracy :≤0.4 ℃
• Room temperature sensor accuracy: ≤0.3 ℃
• Warm-up time : ≤40min
• Height adjustable range: 0 - 20CM
• Bed tilt angle: :±10°
• Integral timer range: ≤24h
• Heater head horizontal : ±90°
• Mattress size: 74CM X64CM
• Transport and storage
Environment Temp: -40℃ - +55℃
Environment Relative Humidity : 运95%
Atmospheric Pressure: 500~ 1060hPa
• Whole unit size: 70CM X 110CMX 190CM(180- 200CM)
• Castor load: 1pc≤200kg 4pcs≤800kg
Package
Each unit is packed one case
Size : 114* 94 * 104cm
Gross weight: ≤190KG
ISO9001 ISO13485 CE