BN-100 Infant Radiant Warmer (Standard)

Part parameters

Packaging Details:
Delivery Time:
Description:

Detailed introduction:

 

BN-100 Infant Radiant Warmer (Standard)

 

Brief introduction:

 

• Microprocessor based servo controlled temperature system
• The microprocessor-controlled unit allows for three modes pre-warm , manual or automatic
• APGAR timer to record therapy time
• Alarm functions: Power failure, Temperature deviation, Temperature sensor fallure , Over temperature
• LED observe light adjustable , brightness adjustable
• Heater head can be adjusted ±90° horizontally
• Convenient X-ray cassette under infant bed
• Tilt angle of infant bed is adjustable
• Transparent protector folded

 

Technical data

 

Power supply AC110/220V 60/50Hz
Power input 1000VA
Operating
conditions
Environment tmperature 18℃~30℃
Environment,relative humidity 30%~75%RH
Environment air velocity of flow <0.3m/s
Air Temperature control range 32℃~38℃
Temperature control accuracy ≤0.5℃
Skin temperature sensor accuracy ±0.3℃
Mattress temperature uniformity
< 2.0 ℃
Infant Bed tilt angle
± 10°
Warm-up time
≤45min
Heater head horizontal
± 90°
Distance from heater to mattress
80cm
Mattress size
67cm*54cm
APGAR timer range ≤24h

 

 

Safety Control Systems

 

• Adopts anti - explosion micro crystaI quartz infrared radiation tube for its radiation source the heating is quick and life-span is long
• Alarm functions for safety includes:Power failure. Temperature deviation
• Temperature sensor failure , Over temperature
• Temperature deviation can be amended in front panel directly
• A second thermal cut- out function for more safety
• Skin temperature sensor fall protect function avoid over temperature

 

Standard configuration & Optional parts

 

Standard configuration:

Main body(including the Radiant source, Control system , Infant bed , Bracket X-ray cassette. Observe light ,I.V.pole.Skin temperature sensor Tray. Mattress. Transparent protector ,Castors

Optional parts:

Drawer, RS-232(485) connector

 

 

Transport and storage

 

Transport and storage:

Environment Temperature: -40℃ ~ +55℃
Environment Relatlve Humidity: ≤ 95%
Atmospheric Pressure : 500-1060hPa

Package

Each unit is packed one case

Size : 120 * 70 * 96cm 

Gross weight: ≤90KG

 

 

ISO9001   ISO13485   CE

 

 