Part parameters
- Packaging Details:
- Delivery Time:
- Description:
Detailed introduction:
BB-200 Infant Incubator (Standard)
Function features
• Microprocessor based servo controlled temperature system
• Alarm functions : Power failure; Over temperature; Temperature deviation ; Fan failure; Temperature sensor failure;
• Humidity is adjustable continuously
• A keypad lock prevent inadvertent changes the setting
• Integral timer to record therapy time
• Skin temperature sensor fall protect function avoid over temperature
• Air temperature, skin temperature , timer and heat power separately displayed by LED
• >37℃ temperature setting
• Silence/reset button for alarml
Product main characteristic
Product main characteristic
• Trough for pulling and pushing , which is convenient to add the water and wash
• Fan with low noise and long life-span
• Temperature deviation and over temperature ould be amended in front panel directly
• A second thermal cut-out function for more safety
• The infant bed inclination angle is adjustable
• Six operating windows . two side access operating windows can be swiveled
• Cupboard for easy storage
Stamdard configuration
Main body (including the transparent hood. control system. infant bed , water trough) ;
I .V.pole; Mattress: Cupboard Castors
Optional parts:
Phototherapy up side unit ; Tray/pole
Phototherapy from up and down sides
RS232(485)connector: Double wall hood
Infant bed pulled from front and side door;
Infant bed pulled from side door ;
Technical data | ||
Power supply | AC110/220V 60/50Hz | |
Power input | 420VA |
|
Operating conditions |
Environment tmperature | 20℃~30℃ |
Environment,relative humidity | 30%~75%RH |
|
Environment air velocity of flow | <0.3m/s |
|
Air Temperature control range |
25℃~38℃ |
|
Skin temperature control range | 32℃~38.5℃ | |
Skin temperature sensor accuracy | ±0.3℃ | |
Temperature fluctuation |
±0.5℃ |
|
Uniformity of mattress temperature |
≤0.8℃ |
|
Warm-up time |
≤45min |
|
Internal noise level |
≤55dB(A) |
|
Infant bed tilt angle |
±10° |
|
Mattress size |
65cm(L)*37cm(W) |
|
Trough capacity |
1200ml |
|
Air filter | 0.5um | |
Transport and storage
Environment Temp: -10℃ ~ +70℃
Environment Relatlve Humidity: ≤ 80%
Atmospheric Pressure : 500-1060hPa
Package
Each unit is packed in two wooden crate
( control unit and cabinet ): 120 * 70 * 96cm N.W.: 80KG G.W.: 110KG
Hood: 97 *56 * 63cm N.W.: 15KG G.W.: 40KG
ISO9001 ISO13485 CE